Chapter 4 - Operation and Administration Menus and Parameters
BreezeACCESS 4900 129 System Manual
4.2.6.2.12 Wireless Link Trap Threshold (AU only)
The Wireless Link Trap Threshold parameter defines the threshold for the wireless
quality trap, indicating that the quality of the wireless link has dropped below (on
trap) or has increased above (off trap) the specified threshold.
The Wireless Link Trap Threshold is in percentage of retransmissions, and the
allowed range is from 1 to 100 (%).
The default is 30 (%).
4.2.6.2.13 Spectrum Analysis
Gaining knowledge of the noise characteristics per channel enables construction
of a relatively noise free working environment. In order to gain information
regarding noise characteristics in the location of the unit, the unit will enter
passive scanning mode for a definite period, during which information will be
gathered. The scanned channels will be all the frequencies included in the
selected sub-band.
Upon activating the spectrum analysis the unit will automatically reset. During
the information-gathering period the unit will not receive nor transmit data. It also
will not be able to synchronize/associate, meaning that it cannot be managed via
the wireless link. During the spectrum analysis period the unit security mode is
changed to promiscuous to enable gathering information regarding all legal
frames received by the unit. At the end of the period the unit will reset
automatically regaining normal operability upon start up.
The Spectrum Analysis submenu includes the following options:
4.2.6.2.13.1 Spectrum Analysis Channel Scan Period
The Spectrum Analysis Channel Scan Period is the period of staying on each
channel during each cycle for information gathering when performing spectrum
analysis.
Range: 2-30 seconds.
Default value: 5 seconds.
4.2.6.2.13.2 Spectrum Analysis Scan Cycles
The Spectrum Analysis Scan Cycle is the number of scanning cycles when
performing Spectrum Analysis.
Range: 1-100 cycles.
Default value: 2 cycles.