Chapter 4 - Operation and Administration Menus and Parameters
BreezeACCESS 4900 135 System Manual
Forced: The Noise Floor value is set manually to the value configured for the
Forced Value parameter (see below). Typically this mode should be used only
for special testing purposes.
Automatic with Minimum Value: If the calculated Noise Floor using the
built-in mechanism is higher than the value configured for the Forced Value
parameter, the calculated value will be used. Otherwise, the Forced Value will
be used.
The default option is Fully Automatic.
4.2.6.2.17.2 Forced Value
The Forced Value parameter enables configuring the Noise Floor to be used if the
selected Calculation Mode is Forced. This is also the minimum value to be used if
the selected Calculation Mode is Automatic with Minimum Value.
If you decided to change the calculation mode to Automatic with Minimum Value
and you still experience problems in the link (long association time, exceptionally
low throughput), try to improve it by increasing the configured Forced Value.
The available range is from -107 to -55 (dBm)
The default value is:
5 MHz bandwidth: -102 (dBm)
10 MHz bandwidth: -99 (dBm)
4.2.6.2.17.3 Show Noise Floor Calculation
Select this option to view the current values of the Noise Floor Calculation
parameters and the Noise Floor Current Value (the actual current value used by
the device).
4.2.6.2.18 Calibration of Noise Floor Indication
The Calibration of Noise Floor Indication feature has been introduced to overcome
possible inaccuracies in the Noise Floor Calculation mechanism. The calibrated
Noise Floor Indication is used for correcting the displayed Noise Floor values
versus the values that are calculated/used by the internal noise floor calculation
mechanism.
The Calibration of Noise Floor Indication submenu includes the following options:
4.2.6.2.18.1 Run Calibration
Select the Run Calibration option to perform a new calibration process. Typically
this should be performed for a new unit when Factory calibration is not available,